m 50 mix design opc 53 grade

  • Home
  • m 50 mix design opc 53 grade
OPC Cement, 53 Grade Cement | Hi-Bond Cement, OPC Cement ...

As per BIS requirements the minimum 28 days compressive strength of 53 Grade OPC should not be less than 53 MPa. For certain specialised works, such as prestressed concrete and certain items of precast concrete requiring consistently high strength concrete, the use of 53 grade OPC is found very useful. 53 grade OPC produces higher-grade concrete at very economical cement content.

Mix design M35 Grade designed as per IS 10262:2009 & IS ...

Mix design M35 Grade designed as per IS 10262:2009 & IS 456:2000 (FOR BANGAlORE REGION) DESIGNED By: G.PRABHAKARAN M.TECh, QA/QC ENGINEER. Mix proportioning for a concrete of M35 grade is given in A·I to A-ll. A·I STIPULATIONS FOR PROPORTIONING. a) Grade designation : M35 b) Type of cement : OPC 53 Grade conforming IS 12269

CONCRETE MIX DESIGN CALCULATION FOR M35 GRADE – …

31-07-2020· Stipulations for Mix Design Concrete Grade designation : M 35Type of cement : OPC 53 grade confirming to IS 8112 Maximum nominal size of aggregate : 20 mm Minimum cement content : 340 kg/m3 Maximum water-cement ratio :…

Top PDF COMPREHENSIVE STUDY ON OPC 53 AND OPC 53 S …

experimental investigation on comparision of opc 53 and opc 53 s cement with ggbs blended cement concretes in m40 grade m raveendra 1, sampathkumar k2 Growing industrial waste have discovered the need to disposal of industrial waste, The waste that have to be disposed can be kept to use in some manner, among the industrial waste processing cementations nature can be replaced as binder matter ...

OPC 53 Archives - Happho

Main Menu. Buy Construction Materials Menu Toggle. Building Materials Menu Toggle. Cement Menu Toggle. OPC-43; OPC-53; PPC; White Cement

M20 Grade Concrete Mix Design - IS10262 Latest Edition ...

14-05-2020· To find the design mix ratio, divide the calculated value of all materials by the weight of cement. Therefore Mix Design Ratio of M20 Grade concrete by weight is Cement: F.A: C.A: Water = 1 : 2.17 : 3.4 : 0.55. Note: This is a Design mix ratio by weight which is different from the Nominal volumetric mix …

MATLAB code for the design of high strength concrete mix ...

08-04-2021· Input data for mix design of HSC5.1. Requirements for proportioning. a) Grade of concrete: M 70. b) Grade of cement: OPC 53 conforming to IS 12,269. c) Silica fume: Conforming to IS 15,388. d) Maximum size of the aggregate : 20 mm. e) Exposure conditions as per Table 3, 5 of IS 456: Severe (for reinforced concrete) f) Workability: 140 mm (slump) g)

Grades of Ordinary Portland Cement Based on IS Codes - The ...

In concrete mix design, for concrete M20 and above we can achieve 8 to 10% saving in cement with the use of OPC 53. This cement grade is used for specialized works such as prestressed concrete components, precast items such as paving blocks, building blocks etc, runways, concrete roads, bridges, and other RCC works where the grade of concrete is M25 and above.

M-20 Mix Designs as per IS-10262-2009 - Civil Engineering ...

By Raj Mohammad Khan Following table shows the M-20 Mix Designs as per IS-10262-2009, hope this helps all civil engineers here M-20 CONCRETE MIX DESIGN As per IS 10262-2009 & MORT&H A-1 Stipulations for Proportioning 1 Grade Designation M20 2 Type of Cement OPC 53 grade confirming to IS-12269-1987 3 Maximum Nominal Aggregate Size 20 […]

FACT CHECK: M30 Grade of Concrete Mix Design Procedure ...

31-03-2020· FACT CHECK: CIVILJUNGLE.COM - Concrete Mix Design IS Code For Concrete mix design, we use, IS 456, and IS 10262. Table of Contents Required Data for M30... FACT CHECK: M30 Grade of Concrete Mix Design Procedure with OPC 53 Cement - CivilJungle

mix design m15 grade concrete using opc 43 grade cement

M 15 Mix Designs as per IS102622009 Civil . M15 CONCRETE MIX DESIGN As per IS 102622009 MORTH A1 Stipulations for Proportioning: 1 Grade Designation : M15: 2 Type of Cement: OPC 53 grade confirming to IS122691987

M30 Grade of Concrete Mix Design Procedure with OPC 53 Cement

30-05-2021· What Is Design Mix M30? Grade designation : M30; Type of cement : OPC 53 Grade conforming IS 12269; Maximum nominal size of aggregate : 20mm; Minimum cement content : 320 kg/m 3 (IS 456:2000) Maximum water-cement ratio : 0.45 (Table 5 of IS 456:2000) Workability : 100-120mm slump; Exposure condition : Moderate (For Reinforced Concrete)

Mix Design M-50 Grade | Concrete Mix Design

The mix design M-50 grade (with Admixture –Sikament) presented here is for reference purpose only. Actual site conditions may fluctuate and consequently, this should be modified as per the location and other factors. M50 Grade concrete is mostly suitably in heavily reinforced structures to …

Concrete Mix Design: Illustrative Example M30 Grade (M20 ...

The following materials are to be tested in the laboratory and results are to be ascertained for the design mix. (a) Cement Used : OPC 53 Grade Confirming to IS 12269. (b) Specific Gravity of Cement : 3.15. (c) Chemical admixture : Super plasticizer confirming to IS 9103. (d) Specific gravity.

Concrete Mix Design | Different Grades of Concrete

17-05-2017· Concrete Mix design of M5, M7.5, M10, M15, M20, M25, M30 and higher grades of concrete is calculated as below: The procedure for finding the different grades of concrete mixes are same. The below mentioned method can be applied to any grade of concrete by changing the values. To make ease in understanding we are finding the Concrete mix design ...

Concrete Mix Design | Concrete Mix Design Calculations Pdf ...

04-11-2020· Concrete Mix Design for M – 20 Grade of Concrete. Following steps for concrete mix design procedure as per IS Code 10262 – 2019,. Step-1 Calculate Target Mean Strength of Concrete. In order that not more than the specified proportion of test results are likely to fall below the characteristic strength, the concrete mix has to be proportioned for higher target mean compressive strength f 'ck.

Concrete Mix Design – M70 Grade of Concrete (OPC 53 Grade)

02-11-2010· Concrete Mix Design – M70 Grade of Concrete (OPC 53 Grade) Concrete mix design – M70 grade of concrete provided here is for reference purpose only. Actual site conditions vary and thus this should be adjusted as per the location and other factors.

m50 mix design with opc 53 grade - alkoholizm-filmy.pl

To design a concrete mix of the desired strength with available materials,, high strength cements came into picture through IS-8112, OPC – 43 and IS- 12269, OPC- 53 grade to take care of these specific requirements All the three grades viz IS 269 (33-grade), IS – 8112 (43 -grade) and IS – 12269 (53 -grade) were ordinary Portland .

Properties of 33, 43 and 53 Grades of Ordinary Portland Cement

🕑 Reading time: 1 minute Properties of 33, 43 and 53 grades of Ordinary Portland Cement such as fineness, setting times, soundness, expansion, compressive strength based on Indian, American and Eurocodes. Ordinary Portland Cement(OPC) is the most widely used cement in the world for producing concrete, mortar, stucco, and non-specialty grouts. . Ordinary Portland Cement has 3 grades based …

Concrete Mix Design: Illustrative Example M30 Grade (M20 ...

Concrete Mix Design Calculation : M20, M25, M30, M40 Grade Concrete Concrete mix design is a procedure of selecting the suitable ingredients of concrete and their relative proportions with an objective to prepare concrete of certain minimum strength, desired workability and durability as economically (value engineered) as possible.

A Comparative Study ON Mechanical Properties of OPC 53 and ...

KEYWORDS : Mechanical properties, GGBS, 53 grade OPC and OPC 53 S cement, partial replacement, compressive strength, split tensile strength and flexural strength..

mix design m15 grade concrete using opc 43 grade cement

M 15 Mix Designs as per IS102622009 – we civil engineers. Jan 29, 2018 · M15 CONCRETE MIX DESIGN As per IS 102622009 & MORT&H A1 Stipulations for Proportioning 1 Grade Designation M15 2 Type of Cement OPC 53 grade confirming to IS122691987 3 Maximum Nominal Aggregate Size 20 mm 4 Minimum Cement Content (MORT&H 17003 A) ...

Mix Design M-50 Grade - Civil Engineering Portal - Biggest ...

Mix Design M-50 Grade. The mix design M-50 grade (Using Admixture –Sikament) provided here is for reference purpose only. Actual site conditions vary and thus this should be adjusted as per the location and other factors. Parameters for mix design M50. Grade Designation = M-50 Type of cement = O.P.C-43 grade Brand of cement = Vikram ( Grasim )

Concrete Mix Design for M50 grade | Civil4M

31-05-2020· Concrete mix Design for M50 Grade concrete with fly ash is as follows; OPC Cement 53 Grade – 450 Kg Fly ash – 110 Kg Water Cement ratio (w/c) – 0.26 Free Water – 145 liters 20mm Metal / Aggregates – 452 Kg 10mm Metal / Aggregates – 412 Kg Crush Sand – 1006 Kg Admixture Dosage – 0.9 % Admixture – 5.04 Kg Density of Concrete – 2580 Kg/cum

Indian Standard ORDINARY PORTLAND CEMENT, 53 GRADE ...

Specific requirements of ordinary Portland cement for manufacture of railway sleepers to be designated as 53-S grade are given in 5.2, Table 3 and 10.1. To differentiate it with normal grade, '53-S grade' shall be marked on the bags/packages for such cement in place of '53 grade'.

M20 Grade Concrete Mix Design - IS10262 Latest Edition ...

To find the design mix ratio, divide the calculated value of all materials by the weight of cement. Therefore Mix Design Ratio of M20 Grade concrete by weight is Cement: F.A: C.A: Water = 1 : 2.17 : 3.4 : 0.55. Note: This is a Design mix ratio by weight which is different from the Nominal volumetric mix ratio.

M30 Grade Of Concrete Mix Design Procedure With Opc 53

M30 Grade Of Concrete Mix Design Procedure With Opc 53. We are a large-scale manufacturer specializing in producing various mining machines including different types of sand and gravel equipment, milling equipment, mineral processing equipment and building materials equipment.

Mconcrete mix design for M50 grade concrete as per latest ...

29-03-2020· 1 Concrete mix design for m50 2 Type of cement used OPC 53 grade cement conforming to IS 269 3 Maximum nominal size of aggregate : 20 mm. 4 Exposure condition : Severe exposure condition defined as per table 3 Page no 18 of IS 456 2000 . 5 Workability : 120 mm (slump) 6 Method of concrete placing : Pumping 7 Degree of supervision : Good